Determine the cop of a refrigerator
WebFeb 22, 2024 · A food refrigerator is to provide a 15,000 kj/h cooling effect while rejecting 22,000 kj/h of heat. calculate the cop of this refrigerator. ... Advertisement taskmasters taskmasters Coefficient of performance or more commonly known as COP is calculated through the equation, COP = ((T₂)/(T₂ - T₁)) where T₂ is the hot temperature and T₁ ... WebThe coefficient of performance (COP) is a measure of efficiency of the refrigerator. The COP of a domestic refrigerator is the ratio of the refrigeration capacity to the energy supplied to the compressor. It can be expressed by equation 3 (Dossat, 1978; Dincer, 2003). P Q in COP 2 1 1 4 m h h m h h (3)
Determine the cop of a refrigerator
Did you know?
WebDetermine the COP of a vapor-compression refrigerator implementing the simple inverse Rankine cycle, employing R134a as refrigerant, with saturated vapor leaving the evaporator at 278 K and saturated liquid leaving the condenser at 300 K. The compressor has an isentropic efficiency of 0.87. WebAnswer (1 of 3): COP ( coeficient of performance ) is the ratio between the Q quantity of heat transferred or removed from a refrigerator system and the W the energy necessary to input into the refrigerator system to produce or remove the quantity of heat from the system. Generally W is more than...
WebApr 5, 2024 · A refrigerator using R-134a rnaintains the ternperature of its compartment at -10°C while ambient temperature A 35°C. Make reasonable assumptions and a) Determine how the pressure levels should change if we replace the working fluid with propane, Orb) Recommend whether propane or R-134a should be used, considering the COP. WebWe have already understood that COP is the ratio of refrigerating effect to the power input. It is basically the amount of refrigerating effect per unit power input. An air conditioner has a COP value 5 means; 1 kW of power input is required to extract 5 …
WebQuestion: Determine the COP of a refrigerator that removes heat from the food compartment at a rate of 5140 kJ/h for each kW of power it consumes. Also, determine the rate of heat rejection to the outside air. (Round the final answers to two decimal places and the nearest whole number, respectively.) The COP is .................. . Weba) Determine the COP of the refrigerator. b) Determine the mass flow rate [kg/hr] of the cooled water that can be produced at the prescribed temperature. c) Determine the rate of entropy generation in the compressor and the expansion valve. d) Determine the second law of efficiency of the cycle, which is the ratio the current coefficient of ...
WebQuestion 3 (1 point) A refrigerator accepts heat at a rate of 10 kW and it consumes power (work) at a rate of 5 kW. Determine the COP of the refrigerator. O 0.50 15 kW 2.0 kW 05 kW ; Question: Question 3 (1 point) A refrigerator accepts heat at a rate of 10 kW and it consumes power (work) at a rate of 5 kW. Determine the COP of the refrigerator.
WebThe coefficient of performance (COP) of reversible or irreversible refrigerator or heat pump is given by. COP R = 1/ ( (Q H /Q L )-1) COP HP = 1/ (1- (Q L /Q H )) where. Q H = the amount of heat rejected to the. high-temperature reservoir. Q L = the amount of heat received from the. low-temperature reservoir. ontario property tax rateWebExpert Answer. Refrigerant-134a enters the evaporator coils placed at the back of the freezer section of a household refrigerator at 100 kPa with a quality of 20 percent and leaves at 100 kPa and-26°C. If the compressor … ontario property title searchhttp://www.mhtl.uwaterloo.ca/courses/me354/tutorials/pdffiles/Winter07_quiz/q3t02_sol.pdf ontario proposed highwayhttp://labman.phys.utk.edu/phys136core/modules/m3/refrigerators.html ontario providing new rapid training programsWebMar 31, 2024 · The Coefficient of Performance (COP) is defined by the ratio of heat dissipation and electrical power intake. It is the parameter by which the air conditioning unit’s performance is evaluated. It shows how effective heating and cooling systems are, following points show the characteristics of COP, ontario prov flowerWebThe food compartment of a refrigerator, shown in Fig. 6-24, is maintained at 4°C by removing heat from it at a rate of 360 kJ/min. If the required power input to the refrigerator is 2 kW, determine (a) the coefficient of performance of the refrigerator and (b) the rate of heat rejection to the room that houses the refrigerator. ontario property tax rates 2022WebSep 9, 2024 · Thus, for a heat pump, the appropriate definition of the coefficient of performance is the heating effect (i.e. Q2) divided by the … ontario proud facebook